The SANCO2 heat pump should:

  • Be located no further than 66ft (20m) from the tank, and no more than 23ft (7m) above it. Additionally, minimizing pipe length to the tank/pod maximizes efficiency
  • Maximum 6 bends, use long-radius elbows, not “street Ls”
  • Be installed outside, with adequate ventilation (see Required Unit Clearances)
  • Be installed in such a way where water can drain without damaging the heat pump

The heat pump can be installed either on a:

  • Preferably a pad or other firm base, or
  • On wall-mounted brackets.

Dimensions

Source: SANCO2 GS4 Installation Manual
Source: SANCO2 GS4 Installation Manual

Required Unit Clearances

Source: Source: SANCO2 GS4 Installation Manual
Source: Source: SANCO2 GS4 Installation Manual

Allow 4” of clearance below the heat pump for the drain plug.

Installation Example and Additional Dimensions

Powering the SANCO2

Electrical Requirements:

Power Supply:240V-1Ph-60Hz
Breaker Size:15A
MCA:7.2A

A quick disconnect must be installed adjacent to heat pump in accordance to NEC and local codes

Main Power Connection

Source: SANCO2 GS4 Installation Manual
Source: SANCO2 GS4 Installation Manual

Refer to Low Voltage Wiring Diagram for low voltage wiring.

Plumbing Connections