Skip to content

Harvest Pod

Location

The Pod is required to be installed in weather-protected space at a minimum, such as a garage, basement, crawlspace, indoor closet, or outdoor closet where there is no risk of freezing.

Recommended to be installed as close to tank as reasonable, and can be:

  • Wall-hung near tank, or
  • above the tank in closet

Dimensions and Clearances

Mininum 24” of clearance is required in front of pod for wiring installation and future service access.

Mounting

Mount to studs or sturdy surface with screws using provided mounting holes.

Power

The pod will require a 120V power outlet for the included 24 VDC power supply (refer to Low Voltage Wiring Diagram).

Internet

The Harvest Pod will require either an Ethernet or WiFi connection. This enables over-the-air updates, access to weather forecasts, and remote monitoring of the system. Ethernet is the most robust and therefore recommended option. See Start Up for more info.

Plumbing Connections

Size
A: Heat Pump Cold1/2” NPT
B: Utility In3/4” NPT
C: DHW Hot3/4” NPT
D: Air Handler Supply1/2” NPT
E: Air Handler Return1/2” NPT
F: Cold Water to Tank3/4” NPT
G: Hot from Tank3/4” NPT
H: AHU Return to Tank1/2” NPT