Tank

Location

The tank can be located no further than 66ft (20m) from the SANCO2 heat pump, and no more than 23ft (7m) below it.

Tank must be installed in an area not subjected directly to outside weather.

Dimensions

Source: SANCO2 GS4 Installation Manual
Source: SANCO2 GS4 Installation Manual
Dimension83 Gal119 Gal
A: Height68-7/8”63-3/8”
B: Hot Water Outlet and PRV60-1/4”56”
C: Heat Pump Return60-1/4”60-1/4”
D: Sensor Port40-5/8”56”
E: Hydronic Return & Cold Water to HP8-3/4”4”
F: Diameter24-1/2”28”
Dry Weight115 lbs345 lbs

Mounting

The tank is a passive storage vessel (no internal heating element). Therefore, there is no required:

  • Pedestal
  • Flue, or
  • Condensing section

Plumbing Connections

83 Gal119 Gal
F: Air Handler Return3/4” NPT1-1/2” NPT
G: Hot Water Outlet3/4” NPT1-1/2” NPT
HPH: Hot Water Return from HP3/4” NPT3/4” NPT
H: Cold Water Inlet/Return to Heat Pump3/4” NPT3/4” NPT
PRV: Pressure Relief ValveValve ProvidedValve Provided